6-7SectionSetting Conditions for Communications with Host by Using Memory Switches
163
6-7-4 Setting the NT Link (1:N) Method (Standard/High-speed)
Set the communication conditions for the NT link (1:N) method at serial port A or
serial port B by following the operation from the System Menu shown below.
The communications speed determines whether the 1:N NT Link is standard or
high-speed.
Standard: Standard 1:N NT Link
High-speed: High-speed 1:N NT Link
Select Maintenance Mode.
Select Memory Switch.
Display the fourth memory switch screen by
pressing the [] (next screen) or [] (previous
screen) touch switch.
Press the touch switch corresponding to the
port at which the NT link (1:N) method (stan-
dard or high-speed) is to be set (Comm. A
Method or Comm. B Method) to display the
setting option NT Link (1:N).
The setting option changes each time the
touch switch is pressed.
In this example, serial port A is used.
Ver 3.10